FLT93S Flow Switch

Category

Brand

Fluid Components International (FCI) Fluid Components International (FCI)

Product Code: FLT93S

Get Product Information

TEKLİF İSTEYİN

FLT93S Flow Switch Details

For Flow Service - Setpoint Range:

  • Water-based Liquids:

0.01 to 3.0 fps [0.003 to 0.9 mps]

  • Hydrocarbon-based Liquids:

0.01 to 5.0 fps [0.003 to 1.5 mps]

  • Air/Gas:

0.25 to 120 sfps [0.08 to 37 smps] at standard conditions of 70° F [21.1° C] and 14.7 psia [1.013 bar(g)].

Accuracy: (whichever reading is higher)

  • Liquids: ± 0.5% reading or ± 0.04 fps [± 0.012 mps]

  • Gases: ± 0.5% reading or ± 2 sfps [± 0.06 nmps]


For Temperature Service:
Accuracy: ± 2° F [±1° C]
Repeatability: ± 1° F [± 0.6° C]

Response Time: As low as 3 seconds.

Enclosure: NEMA 4X/IP66 Rated. Standard: Polyester powder coated aluminum, with single 1" NPT conduit port. Optional: Stainless steel. Optional: Dual-conduit port, aluminum with 1/2" NPT or M20 metric conduit ports.

Compliances and Agency Approvals: FM, FMc, ATEX, IECEx, EAC/TR CU, Inmetro. EQM/UCAS, CE mark. PED, CRN. (UKCA, UKEX pending)
Meets EC directives for EMC and LVD. Probe complies with Canadian Electrical code requirements of ANSI/ISA 12.27.01-2011 as a single seal device.
 

FM/FMc:XP, Class 1, Div. 1 Groups B,C,D, T3A or T4 Ta ≤60°C
DIP, Class II/III, Div. 1, Groups E,F,G, T3A or T4 Ta ≤60°C
Nonincendive for Class I, II and III, Division 2, Groups A,B,C,D,E,F, and G, T3A or T4 -40°C ≤Ta≤60°C; hazardous (classified) locations, indoors and outdoors.
Type 4X
ATEX:Integral:                        II 2 G  Ex db IIC T4…T2 Gb
                                     II 2 D  Ex tb IIIC T135°C…T300°C Db
  Remote enclosure
  + electronics:             II 2 G  Ex db IIC T6 Gb
                                     II 2 D  Ex tb IIIC T85°C Db
  Local enclosure
  + sensor                     II 2 G  Ex db IIC T4…T1 Gb
                                     II 2 D  Ex tb IIIC T135°C…T345°C Db
 
  Pigtail version            II 2 G  Ex db IIC T4…T3 Gb
                                     II 2 D  Ex tb IIIC T135°C…T200°C Db
 
IECEx
(EQM/ECAS):
Integral:                        Ex db IIC T4…T2 Gb
                                     Ex tb IIIC T135°C…T300°C Db
  Remote enclosure
  + electronics:             Ex db IIC T6 Gb
                                     Ex tb IIIC T85°C Db
  Local enclosure
  + sensor                     Ex db IIC T4…T1 Gb
                                     Ex tb IIIC T135°C…T345°C Db
 
  Pigtail version            Ex db IIC T4…T3 Gb
                                     Ex tb IIIC T135°C…T200°C Db

Optional N.I.S.T. Flow Calibration Services
Factory N.I.S.T. calibration in air or water is available as an option for customer specified setpoint(s) or a flow curve based on the media ranges specified above.
 

Flow Element

Materials of Construction: All welded 316L stainless steel for all wetted surfaces.

Process Connection: 

  • Standard: 0.75 inch male NPT

  • Optional: 1 inch male NPT, flanges or retractable sensing element.


Insertion Length:

  • 1.2 inch [30 mm]

  • 2 inches [51 mm]

  • 4 inches [102 mm] 

  • 6 inches  [152 mm]

  • 9 inches  [229 mm]

  • 12 inches  [305 mm]

  • 18 inches  [457 mm]


Customer specified lengths are available as an option.

Operating Temperature: 

  • Standard: -40° to +350° F [-40° to +177° C]

  • Optional: -100° to +500° F  [-73° to +260° C] or -100° to +850° F  [-73° to +454° C]


 

  • Operating Pressure: To 3500 psig [240 bar(g)]


Control Circuit

Operating Temperature: -40° to +140° F [-40° to +60° C]

Universal AC/DC supply. Input terminals and jumpers on circut board select specific power.
 

AC108-132V13W, 100mA max.
AC207-253V*14W, 50mA max.
AC18-28V7W, 230mA max.
DC21-30V7W, 230mA max.

* AC mains preset by factory: FM & FMc as 108-132 Vac; All others as 207-240 Vac 

Relay Contacts: Field configurable dual SPDT or single DPDT rated 6 amps at 115 Vac, 240 Vac or 24 Vdc.

Output Signal: Analog DC voltage related to flow or level/interface signal and proportional to temperature.

Electrical Connection: 1 inch female NPT 

Remote Configuration: Available as an option with customer specified interconnecting cable length.