ST75 Series Mass Flow Meters Details

Warranty: 
ST75, ST75V: 1 year
ST75A, ST75AV: 2 years

Media Compatibility: Air, compressed air, nitrogen, oxygen, argon, CO2, ozone, other inert gases, natural gas, and other hydrocarbon gases.

Pipe/Line Size Compatibility: 1/4" to 2" [ 6 mm to 51 mm]
 

 ST75ST75AST75VST75AV
Vortab flow conditioning  ■■
Dual 4-20 mA outputs■■■■
4-20 mA per NAMUR NE43■■■■
HART or Modbus I/O ■ ■
500 Hz pulse output■■■■
Maximum remote distance50' [15 m]100' [30 m]50' [15 m]100' [30 m]
SIL compliance rating ■ ■
Warranty Standard1 year2 years1 year2 years


Range:*

NPT Line Size1/4"1/2"3/4"1"1 1/2"2"
Min. SCFM0.040.130.220.350.851.40
Min. [NCMH][0,07][0,22][0,38][0,59][1,44][2,38]
Max. SCFM17.3450.6488.88139.95339.31559.27
Max. [NCMH][29,47][86,04][151,00][237,78][576,48][950,20]
Tubing Line Size1/4"1/2"1"
Min. SCFM0.010.050.25
Min. [NCMH][0,01][0,09][0,42]
Max. SCFM3.0221.1599.08
Max. [NCMH][5,14][35,94][168,33]

* Actual range subject to gas type and specific conditions.
 

  • Accuracy: 

Model ST75, ST75 A
Standard: ± 2% reading, ± 0.5% full scale
Optional: ± 1% reading, ± 0.5% full scale

Model ST75V, ST75AV
Standard: ± 1% reading, ± 0.5% full scale
 

  • Temperature Coefficient: (at calibrated conditions) 

With optional extended temperature compensation; valid from 10% to 100% of full-scale calibration
Flow: Maximum ± 0.025% of reading/ºF up to 250ºF [±0.05% of reading/ºC up to 121 ºC]

Repeatability: ± 0.5% reading

Turndown Ratio: Factory set at 3:1 to 100:1

Temperature Compensation: 

  • Standard 40°F to 100°F [4°C to 38°C] 

  • Optional: 0°F to 250°F [-18°C to 121°C] 


Turndown Ratio: 10:1 to 100:1
 

  • Agency Approvals:

FM, FMc:Class I, Division 1, Groups B, C, D; T4 Ta= +60°C;
Type 4X, IP66
Class II/III, Division 1, Groups E, F, G; T4 Ta= +60°C;
Type 4X, IP66
Model ST75 and ST75V also include: Nonincendive for
Class I, Division 2, Groups A, B, C and D; T4 Ta= + 60°C;
Type 4X, IP66
ATEX:Zone 1, Zone 21
II 2 G Ex db IIC T6...T1 Gb
II 2 D Ex tb IIIC T85°C...T300°C Db; IP66/IP67
Ta= - 40°C to + 65°C
IECEx:Ex db IIC T6...T1 Gb;
Ex tb IIIC T85°C...T300°C Db; IP66/IP67
Ta= -40°C to +65°C
Other:EAC/TR CU (Russia), Kazakh MPA, NEPSI, CE Marking, CPA,
PED, EAC/TR CU pressure directive 032-2013, CRN
SIL (ST75A, ST75AV):SIL 1 compliant, safe failure fraction (SFF)
78.5% to 81.1%


Flow Element

Installation:  In-line "T", NPT or tube

Type: Thermal dispersion

Materials of Construction: All-welded 316 stainless steel probe element with Hastelloy-C22 thermowells; 316 stainless steel NPT and tube fittings; ST75 V and ST75 AV flow body is schedule 40 stainless steel.

Process Connection: 

  • T-fitting [NPT female]: 1/4", 1/2", 3/4", 1", 1 1/2" or 2"

  • Tubing: 1/4", 1/2" or 1"


Operating Temperature: 0°F to250°F [-18°C to 121°C] 

Operating Pressure: 

  • T-fitting [NPT female]: 240 psig [16,5 bar(g)]

  • Tube: 600 psig [ 41 bar(g)] 


Flow Transmitter

  • Enclosure:

Rating: NEMA 4X, IP66, IP67
Material:
    Standard– polyester powdered coated, ≤0.4% CU, low/no copper content*2 aluminum
      (*2: Standard effective April 2023)
    Optional– 316 stainless steel
Conduit/Cable Port: Dual 1/2″ NPT or M20x1.5

Input Power: 
DC: 18 Vdc to 36 Vdc
AC: 85 Vac to 265 Vac (*CE Marking approval from 100 Vac to 240 Vac)
 

  • Operating Temperature Range: 0°F to 140°F [-18°C to 60°C]

 

  • Output Signal

Standard
(2) 4-20 mA, user assignable to flow rate and/or temperature
(1) 0-500 Hz pulse for total flow
Output #1 have fault indication per NAMUR NE43 guidelines; user selectable for high (> 21.0 mA) or low (< 3.6 mA)
 

  • Bus Communications  (Models ST75A and ST75AV only)

    HART:  Version 7.  FieldComm Group certified.  Available over output #1; DD file included. 
    Modbus:  RS485 (RTU and ASCII). Standard MS (16 bit), Standard LS (16 bit), and Daniel extension (32 bit).
 

  • Communication Port: RS232C standard

 

  • Digital Display (optional): 2-line x 16 characters LCD. Displays measured value and engineering units. Top line assigned to flow rate. Second line is user assignable to temperature reading, as flow totalizer or alternating. Display can be rotated in 90° increments for optimum viewing orientation.

Would you like to know more about this product?

TEKLİF İSTEYİN